13
Circuit Breaker Instructions:
The motor includes a resettable overload breaker to prevent risk of
personal injury or grain mill damage.
Instructions for resetting overload breaker: Turn the switch to the off
(“O”) position and unplug the motor from the outlet. Remove the motor
from the grain mill. Wait 10 minutes for the motor to cool, then manually
reset the breaker by pressing in on the top of the breaker until it locks.
Important: Before reinstalling the motor, check the grain mill operation
by installing the handle and manually operating the grain mill to make sure
the milling cone isnt jammed or overly hard to turn. If the grain mill is
jammed then the adjustment knob, milling cone and shaft must be removed
to inspect and clear any obstructions.
Caution: If the breaker trips immediately after plugging in or turning on
the motor, do not bypass the breaker and do not use the motor. Contact
Victorio Customer Service at 866-257-4741.
Power Switch
Overload Breaker
ON OFF
Breaker in normal
operang posion
Motor Specicaons: 120 VAC, 60 HZ
Breaker that has
been tripped
Page view 14